lightening arrester

lightening arrester
Product Detailed
Related Categories:Power Accessories
Low residual voltage Long protection distance High energy input capacity Polymeric Lightening Arrester

HYW-3-6KV

Arrester modelArrester rated voltage KVSystem nominal voltage KVDC (U1mA) not less than the reference voltage KVNominal discharge current KAMaximum residual pressure KV (peak)Flow capacity
Only the impact of current waveLightning impulse currentOperating under the impact of current200uS4/10uS
HY5W-3/1062.555.5511.3108.915065
HY5W-6/2065.25.5522.32017.815065
HY10W-3/1032.552.551011.3108.9250100
HY10W-6/2065.25.21022.62017.8250100
HYW-9-12KV,
Arrester modelArrester rated voltage KVSystem nominal voltage KVDC (U1mA) not less than the reference voltage KVNominal discharge current KAMaximum residual pressure KV (peak)Flow capacity
Only the impact of current waveLightning impulse currentOperating under the impact of current200uS4/10uS
HY5W-9/3097.7016.05343029.815065
HY5W-11/39119.419541.53632.715065
HY5W-9/391210.221.5545.33935.715065
HY10W-12/3997.716.010343026.8250100
HY10W-11/36119.419.21041.53632.7250100
HY10W-12/391210.221.31045.33935.7250100
HYW-15-18KV
Arrester modelArrester rated voltage KVSystem nominal voltage KVDC (U1mA) not less than the reference voltage KVNominal discharge current KAMaximum residual pressure KV (peak)Flow capacity
Only the impact of current waveLightning impulse currentOperating under the impact of current200uS4/10uS
HY5W-15/421512.7522.0547.54235.815065
HY5W-18/501815.326.5557.05043.015065
HY10W-15/421512.7522.01047.54235.8250100
HY10W-18/501815.326.51057.05043.0250100
HYW-21-24KV
Arrester modelArrester rated voltage KVSystem nominal voltage KVDC (U1mA) not less than the reference voltage KVNominal discharge current KAMaximum residual pressure KV (peak)Flow capacity
Only the impact of current waveLightning impulse currentOperating under the impact of current200uS4/10uS
HY5W-21/622117.133.0570.06254.215065
HY5W-24/702419.538.0580.07062.015065
HY10W-21/622117.133.01070.06254.2250100
HY10W-24/702419.537.01080.07062.0250100
HYW-36KV
Arrester modelArrester rated voltage KV /DIV>System nominal voltage KV KV KVDC (U1mA) not less than the reference voltage KVNominal discharge current KAMaximum residual pressure KV (peak)Flow capacity
Only the impact of current waveLightning impulse currentOperating under the impact of current200uS4/10uS
HY5W-36/1003630.454.5511510086.715065
HY5W-36/1003630.454.51011510086.7250100