LV Withdrawable Switchgear, MCC

LV Withdrawable Switchgear, MCC
Product Detailed
Related Categories:Power Distribution Equipment
LV Withdrawable Switchgear,LV Switchgear,MCC 1.Upto 660V,6000A 2.50/60Hz 3.ABB,Schneider,GE parts optional 4.IEC60439,GB7251

YMNS LV Withdrawable Switchgear, LV Switchgear, MCC

YMNS low voltage draw out switchboard is comprises of electric power center(PC) and motor control center (MCC). Mainly used for AC 50Hz ,Max work voltage 660v,Max work current 6000A  power plant ,variable power plant,industrial Enterprise user. Our product has high analysis ability ,good function at fixed thermal stability,advanced structure.The low voltage draw out switchboard can store many circuit,the many advantage of the our product as like it  save land area and beauty shape,high protection,easy maintenance.Product is up to standard IEC60439 low voltage swithchboard  and control device,GB7251.1 low voltage swithchboard  and control device

Service condition

1. Ambient temperature: -5'C~+40'C. Average temperature in 24 hours <= 35'C.

2. Altitude: <=2000m.

3. Air humidity at 40'C <=50%. Higher humidity at lower temperature is permitted. Occasional condensation due to temperature variation should be considered.

4. No excessive vibration.

5. No corrosion to electric elements.

Special condition subject to users.

Features and Benefits

1.The optimized footprint uses smaller section sizes when possible. Sections are provided in 22", 30" or 38" widths.

2.Breaker compartment doors have no ventilation openings, thus protecting operators from hot ionized gases vented by the breaker during circuit interruption.

3.A superior bus system offers different levels of protection.  Insulated and isolated bus makes maintenance procedures touch friendly to reduce the risk of arc flash.

4.True closed-door drawout construction is standard with all YMNS equipment. The breaker compartment doors remain stationary and closed while the breaker is racked out from the connect position, through test, to the disconnect position. Doors are secured with rugged 1/4-turn latches.

5.An easy-to-read metal instrument panel above each circuit breaker holds a variety of control circuit devices, including the RELT switch.

6.Each circuit breaker is located in a completely enclosed ventilated compartment with grounded steel barriers to minimize the possibility of fault communication between compartments.

7.Optional safety shutters protect operators from accidental contact with live conductors when the breaker is withdrawn.

8.Easy access to equipment compartments simplifies maintenance of the breaker cubicle and control circuit elements as well as inspection of the bolted bus connections.

9.The conduit entrance area meets NEC requirements.  Extended depth frame options are available in 7" and 14“ sizes for applications requiring additional cable space. The section width also can be increased for additional cable space.

10.A rail-mounted hoist on top of the switchgear provides the means for installing and removing breakers from the equipment. This is a standard feature on NEMA 3R outdoor walk-in construction and optional on indoor construction.

11.Control wires run between compartments in steel riser channels. Customer terminal blocks are located in metal-enclosed wire troughs in the rear cable area. Intercubicle wiring is run in a wireway on top of the switchgear, where interconnection terminal blocks are located.

12.All circuit breakers are equipped with rollers and a guidebar to provide easy and accurate drawout operation.

13.An optional remote racking device reduces the risk of the arc flash hazard by allowing the operator or electrician to move the breaker anywhere between the DISCONNECT and CONNECT positions from outside the arc flash boundary.

14.Optional infrared (IR) scanning windows can be installed in the switchgear rear covers to facilitate the use of IR cameras for thermally scanning cable terminations.

15.YMNS switchgear can be expanded easily to handle increased loading and system changes. Specify a requirement for a fully equipped future breaker to obtain a cubicle that has been set up for additional breaker installation, or add vertical sections without modifications or the use of transition sections.

16.An array of safety interlock and padlocking features are available to accommodate any type of lockout-tagout procedure a customer may have.

17.Optional Power Management:  With the proper devices, facility power can be tracked and controlled.

Specification

rated work frequency

50Hz

rated work voltage

380V,660V

rated insulation voltage

660V

rated work current

horizontal busbar

630A-6000A

Vertical busbar

600A

rated short time withstand power current

horizontal busbar

80kA/1s

Vertical busbar

50kA/1s

rated peak withstand current rating

horizontal busbar

176kA

Vertical busbar

110kA

Plug-ins in main circuit

200kA,400kA

Plug-ins in vice circuit

10A

Industrial frequency withstand voltage

2500V

Max motor control

155kW

grade protection

IP40

operationmode

 

 

 

LV Withdrawable Switchgear, MCC